by Vitesse203
Fri May 16, 2014 11:42 am
Forum: TunerStudioMS
Topic: Changing x axis
Replies: 3
Views: 308

Re: Changing x axis

Project settings had Alpha N selected in project properties. Sorted now thank you.

Paul
by Vitesse203
Fri May 16, 2014 11:19 am
Forum: TunerStudioMS
Topic: Changing x axis
Replies: 3
Views: 308

Re: Changing x axis

Hi Matt

I should have said its the Y axis and it shows TPS adc on both VE table and AFR table. Changing to Alpha N would use TPS not MAP and the control is configured for Speed density already. I want to change the Y axis back to MAP dot and seem unable to do it.

Regards

Paul
by Vitesse203
Thu May 15, 2014 1:40 pm
Forum: TunerStudioMS
Topic: Changing x axis
Replies: 3
Views: 308

Changing x axis

Hi tunerstudio shows my x axis on VE table to be TPS adc and I would like to change it to Map and I can't remember how to change it.

Regards Paul
by Vitesse203
Thu Mar 06, 2014 12:27 pm
Forum: Palm/Phone Based Software
Topic: Android showing different temperature
Replies: 4
Views: 2550

Re: Android showing different temperature

Studying it closer it also seems that rev counter is out by a few hundred rpm and it also loads up gauges that I don't need. Have tried saving revised gauge layout with spark advance and duty cycle gauges changed but it always reverts back to original even when loaded with the ' saved configuration ...
by Vitesse203
Thu Nov 21, 2013 8:19 am
Forum: Palm/Phone Based Software
Topic: Android showing different temperature
Replies: 4
Views: 2550

Re: Android showing different temperature

Sorted it. I had to change the INC files on phone and tablet by connecting them to the computer and copying over Easy Therm INC files.

Regards

Paul
by Vitesse203
Tue Nov 19, 2013 11:15 am
Forum: Palm/Phone Based Software
Topic: Android showing different temperature
Replies: 4
Views: 2550

Android showing different temperature

Hi Android phone and tablet show a different MAT and Coolant temperature on Shadow Dash to my laptop using Tuner Studio. I've used easy therm to update the MS1 which is running the extra code 029y4, and everything else runs ok. Fan switches on at 84°. Idle valve shuts of at 65°, but Android devises ...