Intank Electric Fuel Pump

For discussing injector selection,manifold modifications, throttle bodies, fuel supply system design and construction, and FIdle valves and IACs.
Forum rules
Read the manual to see if your question is answered there before posting. Many users will not reply if the answer is already available in the manual.

If your question is about troubleshooting, configuration, or tuning, you MUST include your processor type (MS-I or MS-II) and code version in your post. If your question is about PCB assembly or modifications, you must also include the main board version number (1.01, 2.2 or 3.0).

If you have questions about MS1/Extra or MS2/Extra code configuration or tuning, please post them at www.msextra.com Such questions posted here will be moved to: a temporary MSextra sub-forum, where they will be removed after 7 days

The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
usagoal
Helpful Squirter
Posts: 40
Joined: Fri Nov 19, 2004 5:27 am
Location: new jersey

Intank Electric Fuel Pump

Post by usagoal »

I need some opinions/advice on my intank electric fuel pump modification I'm working on for my buick. I've already had a sump welded to the bottom of the tank with a "socket" to hold the electric pump & filter sock. I tried my best to design this setup without spending a million dollars and utilizing OEM and existing parts. I'm leaving the original gas gauge sending unit (since it still works) and using the old pickup tube as a return tube. I had drilled a new hole and fitting a 3/8" supply line a few inches away from the sending unit. From this fitting a rubber fuel line (fuel injection rated) will run to the pump mounted in the sump. Now here is where I get a little nervous...the power running to the pump is ran through the sending unit top and along the rubber supply line. It is attached every 2" with nylon cable ties (as nylon is gas resistant) starting from the return line and continuing down the rubber supply line. I tried to leave some slack so the wire does not rip from movements in the tank (vibrations, flexing, etc). I've attached two diagrams to help illustrate this. Does this setup look ok? I even thought about running the wiring through a small 1/8" fuel line (the type used for weed wackers, small engines, etc) that would run parallel to the supply line and secured using ties. I don't know if I'm being paranoid or what. The distance of the wiring is only about 8". Any thoughts would be appreciated. I could also attach photos if needed. Thanks.
You do not have the required permissions to view the files attached to this post.
1962 Buick Skylark 215 V8
Bored and stroked to 266, Port Injection, Pertronix ignition AEM WB 02
1977 28' Mercruiser 351Windsor, TBI, Pertronix ignition, NB o2
Both MS-II 2.891 , V-3 board
Stag76
MegaSquirt Newbie
Posts: 18
Joined: Tue May 09, 2006 4:56 pm
Location: Toowoomba Qld australia

Re: Intank Electric Fuel Pump

Post by Stag76 »

I built an in-tank pump for a Triumph Stag, using a locally sourced Ford pump. I went through the same concerns that you are experiencing, eventually speaking at length to a very helpful local EFI shop, who showed me several pump failures
(after 20 or so years use), some where the pump had overheated and burned the insulation off the supply wire. The result
in all cases was the same - car stopped, no fires or explosions. The main thing they stressed was to use cable more than capable of carring the required current, and to secure everthing as you have done. Turning it on for the first time was a bit stressful, but I soon forgot it was there.
8974Ollie
Helpful Squirter
Posts: 82
Joined: Tue Oct 13, 2009 4:35 pm

Re: Intank Electric Fuel Pump

Post by 8974Ollie »

This link to the Fuel Injection Forum at Pro Turing might be of interest to you.

http://www.pro-touring.com/forum/forumdisplay.php?f=31
fury fan
Helpful Squirter
Posts: 96
Joined: Tue Dec 11, 2007 10:28 am
Location: Indianapolis

Re: Intank Electric Fuel Pump

Post by fury fan »

I don't have anything to add to your ideas, but be aware that the hose used for in-tank submersion is a slightly different grade than for external use.

From a fuel hose paper I saved:

"Standard fuel and oil (SAE 30R7) hose is rated for
low-pressure applications at 50 psi working
pressure up to 3/8" size, and 35 psi for sizes over
3/8". This general-purpose hose contains a light
reinforcement, and the rubber materials can be any
compound that is suitable for fuel, oil and vapors."

"Fuel injection (SAE 30R9) hose or MPI (multi-port
injection) hose is reinforced to handle higher
pressures up to 180 psi. It can be used on all
injection systems that use hose clamps. It is not
designed to replace coupled assemblies on fuel
injection systems."

"Finally, for submersible applications such as on the
in-tank fuel pump, only SAE30R10 hose should be
used, because when the hose fails, the pump will
fail. Hose construction consists of low swell
fluoroelastomer compounds in the tube and cover
that resist gasoline and diesel fuel permeation and
aging. Standard hoses have these fuel-resistant
characteristics in the tube portion only."
Needs to get the toes out of the water and just jump off the diving board!!!
current EFI project:
65 Chrysler 300L, 413, working on inline dual GM TBI units, will run with MS2. Hoping to have factory-style appearance.