need help with wiring layout for controlling additional relay with MS2

For discussing how to choose sensors and create a wiring harness for all Bowling and Grippo versions of the MegaSquirt® EFI controller.
Forum rules
Read the manual to see if your question is answered there before posting. Many users will not reply if the answer is already available in the manual.

If your question is about troubleshooting, configuration, or tuning, you MUST include your processor type (MS-I or MS-II) and code version in your post. If your question is about PCB assembly or modifications, you must also include the main board version number (1.01, 2.2 or 3.0).

If you have questions about MS1/Extra or MS2/Extra code configuration or tuning, please post them at www.msextra.com Such questions posted here will be moved to: a temporary MSextra sub-forum, where they will be removed after 7 days

The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
Flaming_Crossbow
MegaSquirt Newbie
Posts: 1
Joined: Sun Mar 26, 2017 3:06 am

need help with wiring layout for controlling additional relay with MS2

Post by Flaming_Crossbow »

Hi Guys,

I am working on a patch harness for a Magneti Marelli IAW 16 ECU to MS2 conversion for a MV Agusta (Ducati / Fiat) system.

The sensors and accessories are pretty straight forward but can't figure out the ECU power and relays control... :RTFM: Unlike the conventional relay layout like the core wiring diagram in the MS manual with an ignition switch controlled Main relay + an ECU controlled Fuel relay,
MV Agusta uses the following:
- a main relay controlled by the safety switch (kill switch) / ignition key with a low power line to ECU. (middle relay in the diagram)
- a fuel relay (power relay) controlled by the ECU for the fuel pump,coils and injectors (equivalent to MS2) (bottom relay in the diagram)
- a main ecu power relay (Latch relay) for a high power line to the ECU also controlled by the ECU (top relay in the diagram)

Image

The MV Agusta relay board is a single PCB I wish to keep stock.

I considered:
- GND Switching the Latch relay (OEM pin 4) with an unused MS I/O (not sure if possible).
-Bridging the Latch relay control wire with the Fuel relay control wire and doing something with the high power wires (not sure how).
-Keep the Latch relay unused but I doubt that the ignition switch controlled power line is up to the MS power demand and am unsure about unforeseen effects on the system.

Suggestions are very welcome.