Search found 2 matches

by Dkro
Mon Jul 11, 2016 7:21 pm
Forum: MS-II and V2.2/V3 Main Board Assembly, Testing, and Troubleshooting
Topic: Blown main fuse
Replies: 3
Views: 726

Re: Blown main fuse

I will order up a new cap, get my board back together ,installed and hope for another 4 years of fun, the good thing is it happened while I was still in my driveway.
by Dkro
Sat Jul 09, 2016 8:07 am
Forum: MS-II and V2.2/V3 Main Board Assembly, Testing, and Troubleshooting
Topic: Blown main fuse
Replies: 3
Views: 726

Blown main fuse

My truck ran for about 30 seconds then stalled, main 2A fuse was blown and while troubleshooting found that C-16 was shorted out causing the input on U5 to short to ground. removed C-16 and tested controller with stim and all looks good. The board did have a little flux residue and corrosion on it ...