O2 sensor - interface

For discussing how to choose sensors and create a wiring harness for all Bowling and Grippo versions of the MegaSquirt® EFI controller.
Forum rules
Read the manual to see if your question is answered there before posting. Many users will not reply if the answer is already available in the manual.

If your question is about troubleshooting, configuration, or tuning, you MUST include your processor type (MS-I or MS-II) and code version in your post. If your question is about PCB assembly or modifications, you must also include the main board version number (1.01, 2.2 or 3.0).

If you have questions about MS1/Extra or MS2/Extra code configuration or tuning, please post them at www.msextra.com Such questions posted here will be moved to: a temporary MSextra sub-forum, where they will be removed after 7 days

The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
Reda
MegaSquirt Newbie
Posts: 1
Joined: Sun Apr 28, 2013 9:35 am

O2 sensor - interface

Post by Reda »

I am intending to buy a Megasquirt II board
I need to verify the compatibility of the interfaces

I have AutoMeter O2 wideband Air/Fuel Ratio Pro-Comp Ultra-Lite indicator with a 0 to 4 volt output representing 10.0 to 17.0 Air to fuel ratio
The output scale is linear

I prefer to keep the indicator

What is the board expecting by design
How to hook the DC output to the MegaSquirt II O2 sensor input?
Do I need to do any modification to the software?
Thanks
Reda
Matt Cramer
Super Squirter
Posts: 2951
Joined: Sat Jul 03, 2004 11:35 am

Re: O2 sensor - interface

Post by Matt Cramer »

Reda wrote:I am intending to buy a Megasquirt II board
I need to verify the compatibility of the interfaces

I have AutoMeter O2 wideband Air/Fuel Ratio Pro-Comp Ultra-Lite indicator with a 0 to 4 volt output representing 10.0 to 17.0 Air to fuel ratio
The output scale is linear

I prefer to keep the indicator

What is the board expecting by design
An analog voltage with a maximum reading of 5 volts and a minimum of 0 volts. The curve is defined by the software.
How to hook the DC output to the MegaSquirt II O2 sensor input?
Wire the analog output to MS pin 23.
Do I need to do any modification to the software?
Thanks
Reda
[/quote]

Go to Tools -> Calibrate AFR Table and send the settings needed.
Post Reply