Second map sensor placement

The forum to discuss:
- V2.2, V3 assembly,
- V2.2, V3 troubleshooting, and
- Connection troubleshooting
Forum rules
Read the manual to see if your question is answered there before posting. Many users will not reply if the answer is already available in the manual.

If your question is about troubleshooting, configuration, or tuning, you MUST include your processor type (MS-I or MS-II) and code version in your post. If your question is about PCB assembly or modifications, you must also include the main board version number (1.01, 2.2 or 3.0).

If you have questions about MS1/Extra or MS2/Extra code configuration or tuning, please post them at www.msextra.com Such questions posted here will be moved to: a temporary MSextra sub-forum, where they will be removed after 7 days

The full forum rules are here: Forum Rules, be sure to read them all regularly.
Post Reply
h82crash
MegaSquirt Newbie
Posts: 2
Joined: Mon Sep 15, 2014 8:26 am

Second map sensor placement

Post by h82crash »

Does anyone have a pic of the independant baro sensor installation. Just would like to get ideas on how others mounted it. Was thinking double sided foam tape to the back of the main board. Is this ok? Thanks.

Tom
h82crash
MegaSquirt Newbie
Posts: 2
Joined: Mon Sep 15, 2014 8:26 am

Re: Second map sensor placement

Post by h82crash »

Thanks for the help. It is a V3.0 board MS2 running 2.920 firmware. I cut the pins on the sensor and soldered short leads to the necessary points. I then used 3M VHB double sided mounting tape and placed it on the back side of the proto area. Seems very secure and shouldn't see any heat to affect the adhesive.

Image